DUCTLESS MECHANICAL DEMAND CONTROLLED VENTILATION AND AIR EXTRACTION SYSTEM

Aircare AE ensures the rapid and efficient disposal of undesirable odours and condensation from bathrooms and kitchens in new and refurbished residential buildings, offices, hotels and schools.

It can be controlled on demand, and in the event of particular spikes in humidity it can be operated manually to solve the problem. It is the perfect accessory for Arcare ES.

TYPES OF ADAPTABILITY

  • Aircare AE (FRAME-FITTED)

    If you are replacing doors or windows then integrating Aircare into the new frames is the perfect option. It is quick to install without any special masonry work: a 10 cm space between the frame and the counterframe is all you need to accommodate Aircare.

    No added cost: the fitter will install Aircare at the same time as the window or door.

    Do you want to see a preview of the installed product?

    Scroll down the menu to see the different types of adaptability: each option includes an indoor and an outdoor image.

  • Aircare AE (FRAME-FITTED) INTEGRATED

    • Aircare AE
    • Aircare AE
  • Aircare AE (RECESSED)

    Recessing Aircare into the separate counterframe or masonry work around the edges provides a double advantage: glazing is not reduced, and existing doors and windows do not need to be replaced. Aircare remains hidden because it is fully recessed: the only visible element is the casing cover.

    Excellent performance while blending in perfectly with the decor.

    Do you want to see a preview of the installed product?

    Scroll down the menu to see the different types of adaptability: each option includes an indoor and an outdoor image.

  • Aircare AE (RECESSED) UNDER-MOUNTED

    • Aircare AE
    • Aircare AE
    • Aircare AE
  • Aircare AE (RECESSED) OVER-MOUNTED

    • Aircare AE
    • Aircare AE
    • Aircare AE
    • Aircare AE
  • Aircare AE (RECESSED) VERTICAL

    • Aircare AE
    • Aircare AE
    • Aircare AE
    • Aircare AE
    • Aircare AE
    • Aircare AE
  • Aircare AE (RECESSED) IN SHUTTER BOX

    • Aircare AE
    • Aircare AE

WHAT AIRCARE AE LOOKS LIKE FROM THE INSIDE

Aircare AE

PROTRUDING PANEL

Elegant, hi-tech design, easily matches any surroundings.

View the colour options

Aircare AE version:
  • (RECESSED) vertical
  • (RECESSED) horizontal
Aircare AE

FLUSH PANEL

Fully recessed into the wall, this panel is extremely elegant and completely blends in with the decor.

View the colour options

Aircare AE version:
  • (RECESSED) vertical
  • (RECESSED) horizontal
Aircare AE

FRONT PANEL

Pininfarina slim line design that is fully integrated into the frame.

Aircare AE version:
  • (FRAME-FITTED)
Aircare AE

LED Display

If Aircare AE is recessed into the shutter box, the LEDs and air vents alone can be set into the front of the shutter box, keeping the aesthetic impact of Aircare to a minimum.

Aircare AE version:
  • (RECESSED) INTEGRATED IN SHUTTER BOX

WHAT AIRCARE AE LOOKS LIKE FROM THE OUTSIDE

Aircare AE

COVERS

The covers are designed to protect the ventilation vents from the weather and to prevent any rainwater from seeping in.

Aircare AE version:
  • (RECESSED) horizontal
Aircare AE

VENTILATION VENTS

With minimum visual impact, the ventilation vents can be fitted into the facade, at the back or in the architrave of the framework, making them practically invisible from the outside of the building.

Aircare AE version:
  • (RECESSED) vertical
  • (RECESSED) horizontal
  • SHUTTER BOX horizontal
Aircare AE

CUSTOM COVER

Special aluminium cover customised to match the colour of the house or window; when applied to the outside part of Aircare, it makes the device practically invisible.

Aircare AE version:
  • (FRAME-FITTED)
Aircare AE

EQUIPMENT EXTERIOR

In the frame-fitted version, Aircare has an attractive appearance even without the customisable cover, due to the Pininfarina design.

Aircare AE version:
  • (FRAME-FITTED)

TECHNICAL DATA

(*) Speed (*) Capacity [m3/h] (*) Sound power level LwA [dB] (**) Sound pressure level Lp (a 3m) [dB] (***) Sound pressure level Lp [dB] Power consumption [W]
1 21 32,6 14,6 25,6 3,2
2 25 34,7 16,7 27,7 4,6
3 36 40,4 22,4 33,4 8,3
4 45 45,1 27,1 38,1 11,3
5 61 53,6 35,6 46,6 16,7

(*) Measurements taken in compliance with standard EN 13141-8.

(**) Data provided to enable comparison with the declarations of the competition.

(***) This evaluation refers to measurements taken in the middle of a room in a standardised environment. A standardised environment has a reverberation time of 0.5 seconds.

Do you want technical documentation?

You can compare the three different Aircare options.

COLOUR OPTIONS

The front panel comes in two standard finishes: white or anodised aluminium

Aircare AE Aircare AE

or colourless that can be coated with the same colour as the wall (after being treated with a primer).

Aircare AE Aircare AE

COLOUR OPTIONS

The front panel comes in two standard finishes: white or anodised aluminium

Aircare ES in alluminio anodizzato Aircare ES bianco

or colourless that can be coated with the same colour as the wall (after being treated with a primer).

Aircare ES di colore giallo Aircare ES di colore verde