Aircare AF
(Air Filtration)
DUCTLESS MECHANICAL DEMAND CONTROLLED VENTILATION AND AIR FILTRATION SYSTEM
Aircare AF ensures the correct air change flow in new and refurbished residential buildings, offices, hotels and schools. Unlike Arcare ES, it does not have a heat recovery unit, making it suitable for moderate climates (A-B-C).
The device controls the relative humidity indoors, eliminating the risk of condensation, mould and fungus growth with extremely low energy consumption; it incorporates a filter that eliminates 98% of fine particles 2.5 µm in diameter plus all PM10, in addition to pollen, dust mites, spore and even bacteria of more than 0.4 µm. It lowers the level of CO2, dilutes VOC and completely eliminates the risk of Radon.
Aircare AF comes in two versions:
- AF+ to fit into door and window frames (for profiles of up to 80 mm thick)
- AFL to fit into door and window frames (for profiles of up to 170 mm thick) or recessed
WHAT AIRCARE AF LOOKS LIKE FROM THE INSIDE
PROTRUDING PANEL
Elegant, hi-tech design, easily matches any surroundings.
Aircare AFL version:
- (RECESSED) vertical
- (RECESSED) horizontal
FLUSH PANEL
Fully recessed into the wall, this panel is extremely elegant and completely blends in with the decor.
Aircare AFL version:
- (RECESSED) vertical
- (RECESSED) horizontal
FRONT PANEL
Pininfarina slim line design that is fully integrated into the frame.
Aircare AF+ & AFL version:
- (FRAME-FITTED)
WHAT AIRCARE AF LOOKS LIKE FROM THE OUTSIDE
COVERS
The covers are designed to protect the ventilation vents from the weather and to prevent any rainwater from seeping in.
Aircare AFL version:
- (RECESSED) horizontal
VENTILATION VENTS
With minimum visual impact, the ventilation vents can be fitted into the facade, at the back or in the architrave of the framework, making them practically invisible from the outside of the building.
Aircare AFL version:
- (RECESSED) vertical
- (RECESSED) horizontal
- SHUTTER BOX horizontal
CUSTOM COVER
Special aluminium cover customised to match the colour of the house or window; when applied to the outside part of Aircare, it makes the device practically invisible.
Aircare AF+ & AFL version:
- (FRAME-FITTED)
TECHNICAL DATA
Aircare AF+
(*) Speed | (*) Capacity [m3/h] | (*) Sound power level LwA [dB] | (**) Sound pressure level Lp (a 3m) [dB] | (***) Sound pressure level Lp [dB] | Power consumption [W] |
---|---|---|---|---|---|
1 | 15 | 35 | 17 | 2,8 | |
2 | 23 | 42 | 25 | 4,4 | |
3 | 29 | 46 | 28 | 6,2 | |
4 | 35 | 47 | 30 | 8,9 | |
5 | 41 | 52 | 34 | 12,6 |
Aircare AFL
(*) Speed | (*) Capacity [m3/h] | (*) Sound power level LwA [dB] | (**) Sound pressure level Lp (a 3m) [dB] | (***) Sound pressure level Lp [dB] | Power consumption [W] |
---|---|---|---|---|---|
1 | 12 | 28,6 | 10,6 | 21,6 | 1,9 |
2 | 18 | 31,4 | 13,4 | 24,4 | 2,2 |
3 | 28 | 36 | 18 | 29 | 5,7 |
4 | 33 | 38,3 | 20,3 | 31,3 | 7,4 |
5 | 41 | 41,9 | 23,9 | 34,9 | 10 |
(*) Measurements taken in compliance with standard EN 13141-8.
(**) Data provided to enable comparison with the declarations of the competition.
(***) This evaluation refers to measurements taken in the middle of a room in a standardised environment. A standardised environment has a reverberation time of 0.5 seconds.
Do you want technical documentation?
You can compare the three different Aircare options.